One coil on the pole feeds a home two hot legs that mirror each other. You move a meter between the wires and watch why one hot to the neutral reads 120 V and hot to hot reads 240 V.

Open the visualFree, no sign-up. Works on a phone, tablet, computer, or projector.
Two mirror-image waves

What to try

  1. 1On Wired right, set Meter across to A to N, then to A to B. One leg to the neutral reads 120 V. Leg to leg reads 240 V.
  2. 2Set Leg A to Lamp and Leg B to Toaster. The neutral carries only the difference between the two.
  3. 3Pick Heater on one leg and set Meter across to Heater. Both heater wires are on leg A, so it reads 0 V.

NEC 2026 sections it covers

120.5(A)
120/240 V is a nominal system voltage.
250.26
The neutral is the wire that gets grounded.
250.24(C)
The neutral and the panel are tied together at the service.
250.24(B)
The neutral is not bonded again past the service.
250.53(A)(2)
One ground rod usually needs a second electrode.
200.8(C)(1)
A white wire used as a hot is re-marked with tape at both ends.

Section numbers only. Read the full text in your code book. Temperatures and times in the visual are teaching models.